PSC deficiency code 02101: Closing devices/watertight doors

Area 02 Structural conditions

Code 02101 covers the doors and closing devices that keep the ship's watertight subdivision intact: sliding doors into shaft and pipe tunnels, hinged watertight doors between spaces below the freeboard or bulkhead deck, and their controls. The inspector writing it doubts the door would close and hold water if a compartment flooded. Weathertight doors on exposed decks have their own load line code (03107).

What the inspector looks at

Expect to be asked to close a door while the inspector watches, locally and, where fitted, from the bridge.

  • The door closes fully on its own, with nothing (a cable, a hose, a pipe run later) across the opening
  • Sliding doors: local and remote operation, the audible alarm while the door moves, and the manual means
  • Bridge indicators compared with the door's actual position
  • Hinged doors: gasket, every dog bearing on the knife edge, hinges and frame free of wastage
  • Records of door tests and, on passenger ships, drills

Common findings

  • Watertight door to shaft tunnel could not be closed from the bridge
  • Bridge indicator shows door open while door is closed
  • Audible alarm of sliding watertight door not working
  • Rubber packing of hinged watertight door hardened and cut
  • Several closing dogs seized, one missing
  • Cables led through watertight door opening, door cannot close
  • Watertight door held open with a rope

The rule behind it

SOLAS chapter II-1 sets the requirements. Part B-2 covers openings in watertight bulkheads, with separate rules for passenger and cargo ships on the type of door, where it's operated from and how its position is shown. Part B-4 covers keeping watertight doors closed at sea and their periodical operation and inspection, with regular drills on passenger ships. MSC 102 adopted amendments to Parts B-2 and B-4 on watertight integrity, in force from 1 January 2024.

Action codes you are likely to see

A seized dog freed or a cable rerouted during the visit is often marked 10. Gasket renewal, an alarm or indicator repair, or a hydraulic fix that can be finished in port is usually 17. The load line section of the IMO list of detainable deficiencies includes defective closing devices and watertight doors, so a door that can't be closed may lead to 30. See action taken codes.

How to close it

The chief engineer usually owns the repair. The crew can renew gaskets, free dogs, clear the opening and fix leaks; control, alarm and indicator faults may need an electrician or the maker's technician. Wasted frames or knife edges are a steel repair, and class should be involved because the door is part of the approved subdivision. Afterwards test the door locally and remotely, and chalk test a hinged door. Keep the test record, photos and any class report with the Form B. Related: hull damage, bilge pumping and ISM if the faults point to missing maintenance.

Questions

What's the difference between codes 02101 and 03107?

02101 is for watertight doors in the internal subdivision, below the freeboard or bulkhead deck, which must hold water under pressure after flooding. 03107 is a load line code for weathertight doors on exposed decks.

Can a defective watertight door detain the ship?

It can. Defective closing devices and watertight doors are on the IMO list of deficiencies that may justify detention. One worn gasket is usually fixed before departure; a door that won't close at all is treated far more seriously.

How do we prove a hinged watertight door seals after repair?

A chalk test shows whether the knife edge bears evenly on the new gasket all the way round. Record it with the date and who did it. Class may ask for its own test after a structural repair.

Sources

Written by the SuperRonin team from the sources above. Last updated 6 Nov 2026. This page explains the rules; the regulation, the PSC officer and your flag and class have the final word. If something here doesn't match what you see on board, write to [email protected] and we'll correct it.

Track each deficiency to closure

SuperRonin keeps your fleet's certificates, surveys and PSC inspections. Enter the deficiencies from Form B and one click turns each into a condition with the due date its action code gives, so the office sees what is open and the bell rings before the date. Free during the pilot.

Other codes in Structural conditions