PSC deficiency code 11112: Launching arrangements for survival craft

Area 11 Life-saving appliances

Code 11112 covers the gear that gets a lifeboat or davit-launched liferaft into the water: davits, winches and brakes, falls, sheaves, limit switches, the remote control wire, gripes and, on free-fall boats, the ramp and release. The rescue boat's davit has its own code (11113), and the lifeboat and its hooks go under 11101. The inspector's doubt is whether the craft could be lowered under control with people in it.

What the inspector looks at

Most inspectors want the boat swung out and lowered, often to the water.

  • davit arms, sheaves and pins moving freely, without seized parts or heavy wastage
  • the winch brake holding the load, and the centrifugal brake controlling lowering speed
  • falls: condition, and the dates last turned end for end and renewed
  • limit switches, and the remote control wire that lets someone inside the boat lower it
  • gripes and their quick release
  • on free-fall lifeboats, the hydraulic release and the arrangement for simulated launching
  • weekly and monthly inspection records and the annual and five-yearly reports

Common findings

  • Lifeboat could not be lowered, winch brake slipping
  • Falls not turned end for end, renewal date passed
  • Davit limit switch inoperative
  • Remote control wire seized
  • Sheaves seized and corroded, no evidence of greasing
  • Annual thorough examination of launching appliances overdue

The rule behind it

SOLAS chapter III, regulation 16 covers survival craft launching and recovery arrangements, and regulation 20 covers maintenance and the weekly and monthly inspections. Under regulation 20, falls are turned end for end at intervals of not more than 30 months and renewed when deterioration makes it necessary or at intervals of not more than 5 years, whichever is earlier. The LSA Code, chapter VI, gives the requirements for launching appliances. The annual and five-yearly thorough examinations, including winch brake tests, follow IMO resolution MSC.402(96), mandatory through SOLAS chapter III.

Action codes you are likely to see

Survival craft and their launching arrangements appear among the examples of detainable deficiencies in the IMO port State control procedures, so a davit or winch that can't lower the boat under control can be written as 30. Falls past their renewal date are usually 17, and badly deteriorated falls can lead to 30. Greasing issues tend to be 16 or 17, record gaps 16 or 18. See action taken codes and what to do after a PSC detention.

How to close it

The crew can free and grease sheaves, clear the remote control wire and turn falls end for end, recording each job. Brake and winch repairs, and the tests after them, need a service provider authorised under MSC.402(96), whose report states the tests and results. New falls come with the maker's certificate. Then lower the boat in front of the inspector and log it as a drill. Keep the report, certificate, photos and drill entry with the Form B. Related: lifeboats, rescue boats, inflatable liferafts and on board training and instructions.

Questions

How often must lifeboat falls be renewed?

SOLAS requires falls to be turned end for end at intervals of not more than 30 months and renewed when they have deteriorated or at intervals of not more than 5 years, whichever comes first.

Who can test the lifeboat winch brake?

The brake tests within the annual and five-yearly thorough examinations are done by a service provider authorised under MSC.402(96), usually the maker or a station it approves. The crew does the routine checks and greasing.

Can PSC detain a ship if the lifeboat can't be lowered?

It can. A boat that can't be launched because of a davit, winch or brake defect is usually treated as a ground for detention until the repair is made and the boat has been lowered successfully.

Sources

Written by the SuperRonin team from the sources above. Last updated 6 Nov 2026. This page explains the rules; the regulation, the PSC officer and your flag and class have the final word. If something here doesn't match what you see on board, write to [email protected] and we'll correct it.

Track each deficiency to closure

SuperRonin keeps your fleet's certificates, surveys and PSC inspections. Enter the deficiencies from Form B and one click turns each into a condition with the due date its action code gives, so the office sees what is open and the bell rings before the date. Free during the pilot.

Other codes in Life-saving appliances