LISCR TEC-005: International Maritime Dangerous Goods Code (IMDG Code) And Medical Oxygen Carriage Requirements

This notice sets out the Administration's requirements for carrying the IMDG Code and its Supplement on board and for the carriage, location and maintenance of medical oxygen cylinders. It updates the previous version to extend applicability to chemical and gas carriers while excluding crude oil tankers, to mandate the latest IMDG Code Supplement, and to define trained competent personnel for annual servicing.

Issued by
Liberia Maritime Authority
Number
TEC-005
Date
4 Feb 2025
Applies to
All vessels carrying as cargo dangerous goods as defined in regulation 1 of SOLAS 74 Chapter VII, all ships irrespective of type and size carrying as cargo substances, material or articles identified in the IMDG Code as marine pollutants, and chemical and gas carriers; does not apply to crude oil ta
Refers to
SOLAS 74 Chapter VII, as amended, MARPOL, Annex III, as amended, IMDG Code, as amended

Key points

  • The Notice applies to all vessels carrying as cargo dangerous goods as defined in regulation 1 of SOLAS 74 Chapter VII, to all ships irrespective of type and size carrying as cargo substances, material or articles identified in the IMDG Code as marine pollutants, and to chemical and gas carriers; it does not apply to crude oil tankers or to ship's stores and equipment. (p. 1)
  • Ships of the Administration carrying as cargo dangerous goods or substances identified as a marine pollutant in package form must have on board the latest copy of both Volume 1 and Volume 2 of the IMDG Code; ships carrying dangerous goods in package form or in solid bulk form or marine pollutants must also have on board the latest copy of the IMDG Code Supplement. (p. 2)
  • The MFAG requires a minimum of 44 liters/ 200 bars of medical oxygen, provided as one 40 liter/200 bars cylinder in the hospital with a flowmeter for two persons plus a portable set with a 2 liter/200 bars cylinder and spare (or additional spares where port restrictions apply, provided at least eight hundred (800) litres is available), or as two 20 liter/200 bar cylinders, or as four 10 liter/200 bar cylinders, each arrangement able to supply oxygen to at least two persons simultaneously. (p. 2)
  • Medical oxygen may be located inside or outside the hospital; if inside, the space must be properly ventilated and cylinders protected from damage; if outside, cylinders must be in a protected location not exposed to excessive heat, flames or a corrosive atmosphere; the location must be acceptable to the vessel's classification society. (p. 2)
  • Medical oxygen cylinders and resuscitation equipment must be inspected and serviced annually by trained competent personnel, for example a vessel's licensed deck officer such as 2nd Mate or Chief Mate who has completed Medical Care on board training, acceptable to the vessel's classification society; cylinder contents must be checked or changed per manufacturer's instructions or every three years, and cylinders hydrostatically tested every five (5) years unless the manufacturer specifies a different interval.

Key points by AI from the PDF, with page numbers. Read the original before acting.