LISCR Marine Advisory 25/2026: Concentrated Inspection Campaign (CIC) On Shipboard Safety Items

LISCR requires a Concentrated Inspection Campaign self-assessment checklist on shipboard safety items to be completed by the Master and Chief Engineer before any flag inspection and presented to the attending inspector, with deficiencies reported under Deficiency Code 7130. The advisory includes a 26-item questionnaire covering fire safety and life-saving appliances and rules for safe operational testing.

Issued by
Liberia Maritime Authority
Number
Marine Advisory 25/2026
Date
4 Nov 2026
In force from
4 Nov 2026
Applies to
Vessels undergoing any type of LISCR inspection (Annual/Bi-annual/Quarterly Safety Inspection, Special Safety Inspection, ISM/ISPS/MLC Audit, International Hazardous Material inspection)
Refers to
Safety of Life at Sea (SOLAS), Chapters I, II-2, III, and IX, International Fire Safety Systems Code (FSS Code), International Life-Saving Appliance Code (LSA Code), MSC.402(96), International Safety Management Code (ISM Code), MARPOL 73/78, Annex I, Res. A.393(10)

Key points

  • The CIC must be fully completed by the Master and Chief Engineer before any type of LISCR inspection, including Annual/Bi-annual/Quarterly Safety Inspection, Special Safety Inspection, ISM/ISPS/MLC Audit (Intermediate/Initial/Interim/Special), and International Hazardous Material inspection, and a copy of the completed CIC checklist provided to the flag state inspector prior to commencement of the flag inspection. (p. 1)
  • The CIC questionnaire must be completed as a shipboard self-assessment before any type of LISCR inspection, with objective evidence recorded for each answer; an item must not be marked Yes solely because a certificate or checklist is present. (p. 2)
  • Do not carry out an operational test while cargo operations, passenger operations, bunkering, or another activity makes the test unsafe, and record as comments if a particular item test could not be done; if objective evidence indicates a serious deficiency affecting fire safety or abandonment capability, stop unsafe testing, place compensating measures in effect, notify the Company, and contact the LISCR Duty Officer for guidance.
  • LISCR inspectors must support any No response with detailed remarks and objective evidence; serious deficiencies may warrant expanded inspection, notification to the Flag Administration, requirement for immediate corrective action, requirement for Dispensation Letter, Class Actionable Item or a Condition, or consideration of detention or operational restrictions where the deficiency presents a serious risk to the vessel, crew, passengers, or the marine environment. (p. 2)
  • All deficiencies identified within the scope of this campaign must be reported by LISCR inspectors using Deficiency Code 7130 (Concentrated Inspection Campaign), with the applicable statutory deficiency code also recorded where appropriate. (p. 3)