LISCR Marine Advisory 03/2026: Engine Room Fire Prevention - Compliance with Safety Regulations, Marine Notices, And Mandatory Engine Room Safety Standards
This Marine Advisory reinforces mandatory engine room fire prevention requirements for Liberian-flagged vessels following recent fire incidents, setting out required compliance actions, common deficiencies, and lessons learned to ensure conformity with safety regulations.
- Issued by
- Liberia Maritime Authority
- Number
- Marine Advisory 03/2026
- Date
- 25 Feb 2026
- Applies to
- Liberian-flagged vessels
- Refers to
- SOLAS Chapter II-2, ISM Code, Sections 1.2.2, 7, 10, International Code for Fire Safety Systems (FSS Code), MSC.1/Circ.1321, Marine Notice FIR-001, Marine Notice INS-001, Marine Notice SAF-003, Marine Advisory 02/2026
Key points
- The Advisory reinforces the mandatory compliance requirements that govern Engine Room fire prevention, fire protection readiness, and safe machinery-space operations on Liberian-flagged vessels. (p. 1)
- Update Safety Management Systems (SMS) to reflect Engine Room fire trends and lessons learned, ensure emergency shutdown, ventilation closure, and CO₂ activation procedures are clearly documented and practiced, train crew on fuel system integrity, hot-surface shielding, emergency CO₂ activation, ventilation control, and water-mist operation, and drill full-cycle Engine Room fire response including blackout scenarios and smoke-filled conditions. (p. 3)
- Inspect all high-pressure fuel pipes, clamps, and shielding for wear, corrosion, improper torque, or vibration marks and replace any suspect components immediately. (p. 3)
- Restore or replace all missing or deteriorated insulation, remove oil-soaked lagging without delay, test and verify the full closure of all Engine Room flaps, dampers, skylights, and ventilation stops, verify all CO₂ actuating heads are correctly configured and conduct regular activation drills, ensure water-mist systems operate in accordance with their approved design and power-supply arrangement with functional and distribution testing, and ensure fire suits, BA sets, and radios are fully functional with full PPE required for all Engine Room fire responses and drills. (p. 4)
- Comply fully with the safety inspections as per INS-001, including Engine Room fire-risk checks, and where crew are permitted to perform inspections and maintenance per FIR-001, ensure they have the proper training and are provided with the necessary maker's instructions. (p. 4)
Key points by AI from the PDF, with page numbers. Read the original before acting.
Get new LISCR documents in your bell and inbox
SuperRonin keeps your fleet's certificates and surveys, and sends each new circular of your vessels' flag, class and P&I club as one line with a link. Free during the pilot.
More from LISCR
- Marine Security Bulletin 48/2026: Unauthorized Boarding in Gulf of Aden · 18 Nov 2026
- Marine Security Bulletin 47/2026: Vessel attack in the Arabian Gulf · 17 Nov 2026
- Marine Security Bulletin 46/2026: Vessel attacks in the Strait of Hormuz · 13 Nov 2026
- SAF-020: New SOLAS regulation II-1/3-13 on Lifting appliances and Anchor Handling Winches · 12 Nov 2026
- Marine Advisory 26/2026: Compliance with Amendments of 2022 to Maritime Labour Convention, 2006, as amended (MLC, 2006) · 12 Nov 2026